We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.
Problems/Comments
Emcon conducted mass UST closures (1998) under contract to BCX, under contract to ADOT. No sampling of stockpiled soil was conducted, and elevated lead (although not likely a problem) was detected beneath waste oil tank. Shannon & Wilson returned to the site in 2000 to sample the stockpile and drinking water well. The stockpile was only above PQLs for one analyte; diesel range organics up to 1,140 mg/kg. This stockpile has since been used in excavation activities on-site. The drinking water well was tested for MTBE and results were non-detect.
Action Information
Action Date | Action | Description | DEC Staff |
---|---|---|---|
3/22/1999 | Leaking Underground Storage Tank Release Confirmed - Petroleum | LUST Site created in CSP for source area ID 77521 Upon receipt of report by Emcon. Soil was screened as contaminated and stockpiled onsite. No samples were collected from stockpile. | Former Staff |
3/22/1999 | Underground Storage Tank Site Characterization or Assessment | Report received. | Former Staff |
3/22/1999 | Site Added to Database | Former Staff | |
5/10/2000 | Leaking Underground Storage Tank Cleanup Initiated - Petroleum | 35 cubic yards of soil removed and stockpiled onsite. Bottom samples yield clean hole for the most part. Site likely ready for closure. | Former Staff |
8/21/2002 | Update or Other Action | RECKEY has automatically been generated. | Cynthia Pring-Ham |
1/28/2004 | Update or Other Action | Transferred DEC staff lead from John Carnahan | Cynthia Pring-Ham |
12/22/2004 | Update or Other Action | Update Lat/Long, Topozone Pro aerial photo, USGS Fairbanks C-5 Quad, scale 1:10,000. | Kim DeRuyter |
2/23/2006 | Site Closure Approved | ADEC issued a NFA determination for the ADOT Nenana Maintenance Station. All soil levels met the most stringent ADEC cleanup levels. Groundwater was not sampled however, the on-site drinking water well and the City well which is located approximately 1300' from the site showed non-detect for contaminant levels. | Deborah Williams |
Contaminant Information
Name | Level Description | Media | Comments |
---|---|---|---|
For more information about this site, contact DEC at (907) 465-5390. |
Control Type
Type | Details |
---|---|
No ICs Required |
Requirements
Description | Details |
---|---|
Advance approval required to transport soil or groundwater off-site. |
There are no documents for this site report.
Hazard ID | Site Name | File Number |
---|---|---|
26544 | ADOT&PF Nenana Maintenance Station Class V Injection Well | 110.38.012 |