Site Report: AT&T Alascom Neklason Lake Relay
Site Name: | AT&T Alascom Neklason Lake Relay |
---|---|
Address: | Engstrom Road, North of Bogard Road, Palmer, AK 99645 |
File Number: | 2245.38.025 |
Hazard ID: | 121 |
Status: | Cleanup Complete |
Staff: | No Longer Assigned, 9074655229 dec.icunit@alaska.gov |
Latitude: | 61.620000 |
Longitude: | -149.256389 |
Horizontal Datum: | NAD83 |
![]() | ![]() |
![]() | ![]() |
We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.
Problems/Comments
EPA START team inspected garage area where prior PCB spill and clean-up occurred (1983). Soil samples collected at the southern dump site/burn pit and at the garage building in an area of unstained soil. TPH was detected in 3 of 5 samples ranging from 30-70ppm and PCBs detected in one sample at 290ug/kg. Phase I investigation for entire facility conducted in 1995 by AT&T Alascom identified other areas of concern that were unrelated to former military operations. The garage building was used to store transformers when site was an operating White Alice Communications System facility. 10,000g and 3,000g USTs used by U.S. Air Force to store diesel were removed in 1991, ADEC issued cleanup NFA letter in 1992. 14.42 acre property, 3/4 miles South of Neklason Lake. Drinking water well on site serving one worker. The elevation is ~128 m (419 feet).
Action Information
Action Date | Action | Description | DEC Staff |
---|---|---|---|
10/15/1983 | Interim Removal Action Approved | Between 6-25 October 83, Crowley Environmental Services conducted corrective action activities at the PCB-contaminated areas. No final confirmation samples were taken. | Donald Seagren |
3/2/1999 | Update or Other Action | EPA Site Discovery. | Bruce Wanstall |
3/27/2000 | Preliminary Assessment Approved | EPA START Preliminary Assessment completed. | Bruce Wanstall |
1/24/2001 | Site Added to Database | PCBs detected. | Bruce Wanstall |
1/24/2001 | Site Ranked Using the AHRM | Preliminary ranking. | Bruce Wanstall |
2/27/2003 | Update or Other Action | Responsible Party field changed based on new information from PacificCorp Environmental Remediation Company. | Elizabeth Stergiou |
4/14/2005 | Update or Other Action | File number issued 2245.38.025. | Aggie Blandford |
5/27/2005 | Update or Other Action | After reviewing the file and report, sent e-mail to Rachelle Hannon (PacifiCorp) for update information to be able to close this site. | Donald Seagren |
6/9/2005 | Site Number Identifier Changed | Per Don Seagren's request, changed Spill Date from 4/3/2000. | Former Staff |
6/22/2005 | Update or Other Action | Reviewed 98 Phase II Site Assessment report. Based on the 98 Phase II report, 00 PCB cleanup report and file review, site closure is appropriate. Sent e-mail to PERCO manager to confirm there are no outstanding issues ADEC is not aware of. Closure will be approved upon response. | Donald Seagren |
6/27/2005 | Site Closure Approved | Site assessment showed that PCB's were the only contaminant exceeding ADEC cleanup levels. PCB corrective action was completed in December 98. All remaining known contamination is below ADEC cleanup levels. | Donald Seagren |
6/28/2005 | GIS Position Updated | Using Figure 1.2 from a Phase II Site Investigation Neklasson Lake Communications Site, dated January 11, 1998 from Woodward-Clyde Consultants, a Neklason Lake Radio Relay Preliminary Assessment Report, dated September 1999 in conjunction with TopoZone Pro, entered coordinates for this site. Metadata include USGS Topo Map 1:24K/25K, TopoZone Pro Street Map, on a Medium Size Map, View Scale 1:24,000, Coordinate Datum NAD83. Moderate to High degree of confidence in accuracy of location. | Alyce Hughey |
Contaminant Information
Name | Level Description | Media | Comments |
---|---|---|---|
For more information about this site, contact DEC at (907) 465-5390. |
Control Type
Type | Details |
---|---|
No ICs Required |
Requirements
Description | Details |
---|---|
Advance approval required to transport soil or groundwater off-site. |
No associated sites were found.