Site Report: Kulis ANG, TANK ET-5 Bldg 17
Site Name: | Kulis ANG, TANK ET-5 Bldg 17 |
---|---|
Address: | 5005 Raspberry Rd, Anchorage, AK 99503 |
File Number: | 2100.26.272.13 |
Hazard ID: | 22977 |
Status: | Cleanup Complete |
Staff: | Dennis Shepard, 9074512180 dennis.shepard@alaska.gov |
Latitude: | 61.164311 |
Longitude: | -149.971940 |
Horizontal Datum: | WGS84 |
We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.
Problems/Comments
After the tank was pulled TPH remained at 19000 mg/kg
Action Information
Action Date | Action | Description | DEC Staff |
---|---|---|---|
7/31/2006 | Site Added to Database | Former Staff | |
7/31/2006 | Conditional Closure Approved | letter issued to base 12/17/1993 noting that is the contaminated soil is exposed in the future it will need to be handled in accordance with state and federal regulations. | Debra Caillouet |
7/31/2006 | Institutional Control Record Established | etter issued to base 12/17/1993 noting that is the contaminated soil is exposed in the future it will need to be handled in accordance with state and federal regulations. | Debra Caillouet |
7/31/2006 | Leaking Underground Storage Tank Cleanup Initiated - Petroleum | I entered this backdated action on 7/19/07. DEC has evaluated that no physical soil removal is necessary. | Bill Janes |
7/31/2006 | Leaking Underground Storage Tank Release Confirmed - Petroleum | LUST Site created in CSP for source area ID 75906 (Added by System) | Debra Caillouet |
7/31/2006 | Update or Other Action | RECKEY has automatically been generated. | Former Staff |
8/1/2006 | Update or Other Action | File number issued 2100.26.272.13. | Aggie Blandford |
3/28/2012 | Site Characterization Workplan Approved | Work Plan for Contaminated Soils Investigation and Remediation, Former Kulis Air National Guard Base, Buildings 16 and 17, Anchorage AK | Debra Caillouet |
6/18/2012 | Site Characterization Workplan Approved | Building 17 WP Amendment, Rev1-0, Kulis Building 17 Site Characterization Work Plan, Anchorage AK June 2012 | Debra Caillouet |
2/8/2013 | Site Characterization Report Approved | Closure Report for Building 17 Contaminated Site, Former Kulis Air National Guard Base, Anchorage AK, January 2013 ADEC reviewed the referenced report and the supplemental letter providing the clarification of the monitoring well installation and groundwater sampling. ADEC concurs that the site does not require institutional controls as there is no petroleum contamination remaining and the remaining tetrachloroethylene in soil is below the direct contact levels and it has been demonstrated that groundwater has not been impacted. Please decommission the monitoring well in accordance with the Monitoring Well Guidance dated November 2011 and provide the details of the decommissioning to this office. When this is accomplished ADEC will remove the Institutional Controls and issue a Cleanup Complete decision. | Debra Caillouet |
2/22/2013 | Institutional Control Record Removed | The Alaska Department of Environmental Conservation (DEC) has reviewed Closure Report for Building 17 Contaminated Site, Former Kulis Air National Guard Base, Anchorage AK, January 2013, the supplemental letter providing the clarification of the monitoring well installation and groundwater sampling and the Monitoring Well decommissioning letter report. These documents together meet the requirements of 18 AAC 75.380, Final Reporting Requirements. There is no petroleum contamination remaining at the site and the low levels of tetrachloroethylene remaining do not pose a risk to human health or the environment. The DEC has determined that the cleanup is complete subject to a future determination that the cleanup is not protective of human health, safety, or welfare, or of the environment. The institutional controls that had been placed upon this site are removed from our database. | Debra Caillouet |
2/22/2013 | Exposure Tracking Model Ranking | Initial ranking with ETM completed for source area id: 75906 name: autogenerated pm edit - Kulis ANG, TANK ET-5 Bldg 17 | Debra Caillouet |
Contaminant Information
Name | Level Description | Media | Comments |
---|---|---|---|
Tetrachloroethene | Between Method 2 Migration to Groundwater and Human Health/Ingestion/Inhalation | Soil | Groundwater is 70 feet below ground surface and has not been impacted |
DRO | < Method 2 Most Stringent | Soil |
Control Type
Type | Details |
---|---|
No ICs Required |
Requirements
Description | Details |
---|---|
Advance approval required to transport soil or groundwater off-site. |
There are no documents for this site report.