Skip to content Skip to content

Site Report: Galena AFS/Airport - ST009 - UST 1572

Site Name: Galena AFS/Airport - ST009 - UST 1572
Address: Galena Airport, Galena, AK 99741
File Number: 860.26.003
Hazard ID: 23150
Status: Active
Staff: Jamie McKellar, 9074515175 jamie.mckellar@alaska.gov
Latitude: 64.739393
Longitude: -156.955986
Horizontal Datum:WGS84

We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.

Problems/Comments

UST 1572 first stored diesel, but was later used as a waste oil tank. It was removed in 1998 with no sampling conducted, and had further investigation in 1999 and 2001. The 1999 investigation documented only limited DRO contamination, however, the 2001 investigation found higher DRO concentrations, as well as BTEX above cleanup levels and spotty detections of chlorinated compounds. These investigations were conducted under the Air Force Compliance program, but continuing investigation will be by the Installation Restoration Program of the Air Force as part of the "JP4 Fillstands" IRP Site designated ST009.

Action Information

Action Date Action Description DEC Staff
9/7/1999 Underground Storage Tank Site Characterization or Assessment UST sampling and closure report received. Colin Craven
1/31/2001 Update or Other Action Comments submitted on September 7 sampling and closure report. Colin Craven
5/9/2001 Release Investigation Draft of the continued release investigation received. Colin Craven
11/6/2001 Update or Other Action "Follow On Investigation" report received. Report sent to Wiegers. Colin Craven
11/2/2005 Leaking Underground Storage Tank Release Confirmed - Petroleum LUST Site created in CSP for source area ID 76031 File review and generation of LUST entries specific to each tank. 2001 site investigation found high concentrations of DRO, BTEX, and chlorinated compounds. Continuing investigation under Air Force Installation Restoration Program. See the Contaminated Sites Database "Galena AFS - JP4 Fillstands" entry for current information. Colin Craven
11/2/2005 Site Added to Database Former Staff
11/2/2005 Leaking Underground Storage Tank Cleanup Initiated - Petroleum Includes removal actions conducted under the JP-4 Fillstands contaminated site (see problem statement above) and removal of the UST. Evonne Reese
11/30/2005 Update or Other Action RECKEY has automatically been generated. Former Staff
1/18/2011 Document, Report, or Work plan Review - other ADEC received the Draft ST009 Vapor Intrusion Workplan. Fred Vreeman
2/23/2011 Document, Report, or Work plan Review - other ADEC provided review comments on the ST009 Vapor Intrusion Workplan. Fred Vreeman
5/2/2011 Update or Other Action ADEC received the Air Force responce to comments from the review of Draft ST009 Vapor Intrusion Workplan. Fred Vreeman
7/19/2011 Document, Report, or Work plan Review - other ADEC approved the revised draft ST009 Vapor Intrusion Workplan. Fred Vreeman
5/3/2012 Document, Report, or Work plan Review - other DEC recieved a Draft Site Characterization Report that addresses UST 1572. Fred Vreeman
9/28/2012 Document, Report, or Work plan Review - other DEC provided review comments for the Draft Site Characterization results report. Dennis Shepard
5/29/2013 Document, Report, or Work plan Review - other DEC received a Response to comments and a Draft Final Site Characterization results report. Dennis Shepard
6/14/2013 Document, Report, or Work plan Review - other DEC provided comments for the Draft Final Site Characterization results report. Dennis Shepard
6/14/2013 Document, Report, or Work plan Review - other DEC provided comments for the Draft Final Site Characterization results report. Dennis Shepard
10/8/2013 Site Characterization Report Approved DEC approved the Site Characterization results report for JP-4 Fill-stands, 1572 Liquid Fuel Pump Station, 3,000-gallon UST (Former UST 1572), and 2,000-gallon UST (Former UST 1572-2) (Site ST009), Former Galena Forward Operating Location (FOL), Alaska. Dennis Shepard
9/18/2014 Site Characterization Report Approved DEC Approved the Supplemental Site Characterization Investigation Results Report, JP-4 Fill-stands, 1572 Liquid Fuel Pump Station, 3,000-gallon UST (Former UST 1572), and 2,000-gallon UST (Former UST 1572-2) (Site ST009), Former Galena Forward Operating Location (FOL), Alaska. Monte Garroutte
10/26/2016 Meeting or Teleconference Held A restoration Advisory board meeting was held in Galena Alaska to discuss the general and specific status of site investigations and cleanup at Galena. Dennis Shepard
8/8/2018 Site Visit DEC conducted a site visit at the Former Forward Operating Location in Galena, AK on August 8-9, 2018. A photo log is available in DEC's electronic file. Jamie McKellar
10/29/2018 Site Visit On October 23, 2018, DEC participated in the Technical Project Team (TPT) meeting with representatives from USAF and ADOT&PF. A site visit with inspections of each site was conducted the following day (10/24/2018) in Galena, as well as a regional advisory board (RAB) meeting with members of the community and other interested parties. Jamie McKellar
1/2/2019 Document, Report, or Work plan Review - other REPORT APPROVAL: 2017 Performance Monitoring Report for Sites CPL006, CSS002, OW024, SS014/SS017, SS016, SS022, SS025, ST009, and ST010. Parsons, December 2018. The report presents and evaluates performance monitoring data for sites managed by Parsons with an approved Cleanup Plan or Record of Decision (ROD), and an active remedy installed and operating for fiscal year 2017. Jamie McKellar
4/5/2019 Site Visit On April 2, 2019, DEC staff participated in a Technical Project Team meeting with representatives from USAF, Parsons, CH2M, and ADOT. The TPT meeting was held at the Fairbanks DEC office. On April 3-4, 2019, DEC staff traveled to Galena to participate in meetings with the City Mayor & RAB chair to discuss community concerns about site cleanup; a Proposed Plan meeting for Site DP023, and a community regional advisory board (RAB) meeting to discuss fieldwork completed during the 2018 field season and upcoming 2019 fieldwork. Site visits were also conducted. Jamie McKellar
10/23/2019 Meeting or Teleconference Held On October 22, 2019, DEC participated in the Technical Project Team (TPT) meeting with representatives from USAF and ADOT&PF. A site visit was conducted the following day (10/23/2019) in Galena, as well as a regional advisory board (RAB) meeting with members of the community and other interested parties. Jamie McKellar
8/23/2023 Document, Report, or Work plan Review - other REPORT APPROVED: Final Remedial Process Optimization Evaluation Report, Former Galena Forward Operating Location, Alaska (Parsons, June 2023) Jamie McKellar
11/15/2023 Site Visit DEC, DOT, USAF, and contractors met at the Fairbanks DEC office on May 2, 2023 for a Technical Project Team meeting. The following day a site visit and Regional Advisory Board (RAB) meeting were held in Galena. Meeting minutes for the TPT and RAB meetings were approved on November 15, 2023. Jamie McKellar

Contaminant Information

Name Level Description Media Comments

Control Type

Type Details

Requirements

Description Details

There are no documents for this site report.

No associated sites were found.

Missing Location Data

Because the GIS location data for this site has not been entered, we cannot direct you to its position on the map. Click "Continue" to proceed to the Contaminated Sites Web Map or "Close" to return to the site report.