Skip to content Skip to content

Site Report: JD&S Manns Service Rentals

Site Name: JD&S Manns Service Rentals
Address: 101 Center Ave.; , Kodiak, AK 99615
File Number: 2601.26.012
Hazard ID: 23465
Status: Cleanup Complete
Staff: No Longer Assigned, 9074655229 dec.icunit@alaska.gov
Latitude: 57.788889
Longitude: -152.400000
Horizontal Datum:NAD27

We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.

Problems/Comments

Soil and groundwater contamination found during removal of 4 underground storage tanks. Site no longer operating as a service station (since 6/90). Last staff assigned were Halverson and English.

Action Information

Action Date Action Description DEC Staff
10/2/1990 Site Added to Database Former Staff
10/2/1990 Leaking Underground Storage Tank Release Confirmed - Petroleum LUST Site created in CSP for source area ID 77737 ADD; Petroleum contaminated soil. Former Staff
10/2/1990 Underground Storage Tank Site Characterization or Assessment SA1; Former Staff
11/13/1990 Underground Storage Tank Site Characterization or Assessment SA1R; Requested additional work plan. Former Staff
6/15/1992 Underground Storage Tank Site Characterization or Assessment SA1A; Reviewed/responded to a tank removal report, a phase 1 site assessment report, and release investigation report. Corrective Action Plan requested. Former Staff
7/15/1992 Leaking Underground Storage Tank Cleanup Initiated - Petroleum LCAU; LUST corrective action underway. Former Staff
10/14/1992 Release Investigation RELR; Release investigation report indicates soil and groundwater contamination are present. Requested submittal of additional details on the assessment work and submittal of a corrective action plan. Additional groundwater monitoring data is needed to define the extent of contamination. Former Staff
2/16/1993 Update or Other Action CORR; Letter acknowledged receipt of RZA's response to our 12/14/92 letter. It still appears some petroleum contaminated soil may have been used as backfill onsite. Again requested submittal of a corrective action plan by 2/26/93. As a follow-up Jack Mann sent in a letter, which we received on 2/25, requesting an indefinate extension for submittal of a CAP. Former Staff
11/20/1997 Update or Other Action ADEC sends Notification of Intent to Cost Recover Letter to Current Owner: JACK MANN Former Staff
11/26/1997 Update or Other Action May have different RP. Has letter saying the RP is Chevron.; Jack Mann; 486-5703 Former Staff
11/14/2002 Long Term Monitoring Established Reviewed monitoring reports 2001 & 2002; discussed with previous project manager. Sent letter to all involved parties re: change of ADEC PM. Donald Seagren
11/21/2002 Update or Other Action Review file/reports and develop project sumary/discussion points for upcoming teleconference. Donald Seagren
12/5/2002 Update or Other Action Teleconference to discuss project status/direction. Chevron will monitor in December 02 and add another MW between MW3 & MW4. In the monitoirng report they will propose a future course of action to reach cleanup for the site. Discussed with sit eowner, Jack Mann. File review in prep for call. Donald Seagren
5/13/2003 Long Term Monitoring Established Reviewed December 02 monitoring report. Sent e-mail requesting missing items Chevron committed to during 5 December 02 conference call. Donald Seagren
5/20/2003 Long Term Monitoring Established Reviewed Fourth Quarter 02 monitoring report. Still have not received a response to missing items from action list. Donald Seagren
8/26/2003 Long Term Monitoring Established Reviewed Long term monitoring report and MW5 installation report Donald Seagren
9/16/2003 Update or Other Action Meeting with Chevron and consultant. GW monitoring will continue. Data will be analyzed after 4 quarters to determine best approach for site. Will submit request for ACL's under one of the current methodologies. IC's and LTM would be required as part of any ACL determination. Donald Seagren
1/20/2004 Document, Report, or Work plan Review - other Reviewed 3rd quarter 2003 monitoring report. MW3 submerged due to rains. MW5 not purged and sheen noted. DRO only contaminant exceeding cleanup levels. Donald Seagren
3/1/2004 Document, Report, or Work plan Review - other Reviewed 4th quarter 03 monitoring report Donald Seagren
5/25/2004 Long Term Monitoring Established Reviewed March 04 monitoring report. Still have not received notification from Chevron re: change in project management. Sent e-mail to have samplers listed as qualified persons prior to next sampling event. Donald Seagren
8/6/2004 Long Term Monitoring Established Reviewed monitoring report on 7 June 04 sampling event. MW3 under a large pool of water due to rain. This MW usually exceeds ADEC cleanup levels so missing the data will delay any management decision on the site. Donald Seagren
11/19/2004 Long Term Monitoring Established Reviewed Third Quarter 04 monitoring report. No spearate phase hydrocarbons presnet in any wells.GW flow direction unchanged. MW3 exceed clenaup levels for DRO. All other wells and parameters (GRO, BTEX and MTBE) are below cleanup levels. Risk to human health and the environment unchanged. Donald Seagren
12/3/2004 Update or Other Action File number 2601.26.012 assigned and entered into the Fileroom database and Leaking Underground Storage Tank database. Alyce Hughey
1/28/2005 Update or Other Action Telephon ecall with Maurice Baron, SECOR. Need soil labe data for boring BH-14 to verify conditions in former UST ecxcavation site. Will then NFRAP site with annual LTM until MCLs are met. Donald Seagren
2/4/2005 Document, Report, or Work plan Review - other Reviewed Fourth Quarter event of December 7, 2004. MW3 not sampled due to ice. MW5 not sampled due to insufficient water. No apparent change to risk to human health or the environment. When a switch is made to annual sampling, it will be suggested that the sampling be conducted during a period of annual high water so that all MWs may be sampled to provide useable data. Donald Seagren
2/8/2005 Document, Report, or Work plan Review - other Reviewed missing Site Assessment & Well Replacement report dated 1 March 01. A question remained about possible contamination remainning in the former tank area. Soil boring (BH-14) was completed to approximately 12 below ground surface.Two soil samples exceeded ADEC soil cleanup for benzene. All other constituents were below ADEC cleanup levels. It should be noted that the rentacl center personnel use the unpaved area around BH-14 to wash down equipment. Donald Seagren
2/8/2005 Conditional Closure Approved Reviewed reports and data. No apparent continuing contaminant source. Groundwater not used as a drinking water source. Risk to human health and the environment is low. City ordinance requiring use of City water system will serve as an institutional control. Annual long term monitoroing required until two consecutive sampling events have all contaminats below ADEC Table C cleanup levels. Discussed decision with property owner. Donald Seagren
2/8/2005 Institutional Control Record Established Former Staff
2/11/2005 Update or Other Action Telephon ecall with Jack Mann to discuss NFRAP. Mr. Mann will discuss this with his attorney prio r to giving final approval, as the landowner. Either he of his attorney will call back with any further questions. Donald Seagren
10/25/2005 Update or Other Action Coordination with new project manager Bob Jackson of SECOR on project status. Donald Seagren
3/13/2007 Exposure Tracking Model Ranking Former Staff
4/4/2007 Document, Report, or Work plan Review - other Reviewed 06 annual monitoring report. All analytical results were belwo ADEC cleanup levels. No significant change to the risk to human health or the environment. Well re-development and repair to be conducted duirng 2007 Donald Seagren
12/7/2007 Institutional Control Record Removed cleanup complete and site closure approved Donald Seagren
12/7/2007 Long Term Monitoring Complete cleanup complete and site closure approved Donald Seagren
12/7/2007 Site Closure Approved Former Staff
12/7/2007 Document, Report, or Work plan Review - other Reviewed 07 monitoring report. All contaminants in all MWs were below the cleanup levels. This is the second consecutive event meeting cleanup criteria in all MWS. LTM may be terminated & site closed Donald Seagren
3/6/2008 Update or Other Action Met with Chevron and consultant. MWs will be removed following ADEC procedures during the sommer of 2008. Donald Seagren
4/15/2008 Update or Other Action approved monitoring well decommissioning work plan Donald Seagren
6/13/2008 Update or Other Action Site transferred from Don Seagren to Paul Horwath per Linda Nuechterlein. Alyce Hughey
6/16/2009 Document, Report, or Work plan Review - other Reviewed the Well Decommissioning Report, dated May 19, 2008, and received May 27, 2008 at the Soldotna ADEC office, and received from Conestoga-Rovers & Associates (CRA). CRA decommissioned groundwater monitoring wells MW-1, MW-2, MW-3, MW-4, and MW-5 on April 18, 2008 in accordance with ADEC Recommended Practices for Monitoring Well Design, Installation and Decommissioning. Paul Horwath

Contaminant Information

Name Level Description Media Comments
Benzene < Table C Groundwater
DRO < Table C Groundwater
Benzene < Method 2 Most Stringent Soil
DRO < Method 2 Most Stringent Soil

Control Type

Type Details
No ICs Required

Requirements

Description Details
Advance approval required to transport soil or groundwater off-site.

No associated sites were found.

Missing Location Data

Because the GIS location data for this site has not been entered, we cannot direct you to its position on the map. Click "Continue" to proceed to the Contaminated Sites Web Map or "Close" to return to the site report.
Continue     Close