Skip to content Skip to content

Site Report: Stelling Enterprises

Site Name: Stelling Enterprises
Address: 1/8 mile, Wood River Rd.; , Dillingham, AK 99576
File Number: 2540.26.007
Hazard ID: 23484
Status: Cleanup Complete
Staff: No Longer Assigned, 9074655229 dec.icunit@alaska.gov
Latitude: 59.039710
Longitude: -158.457500
Horizontal Datum:

We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.

Problems/Comments

Last staff assigned was English. USS 3643, Lot 14A, Book 27, pg. 91, Bristol Bay Recording Office. Last staff assigned was Halverson.

Action Information

Action Date Action Description DEC Staff
9/18/1991 Underground Storage Tank Site Characterization or Assessment SA1; Site assessment conducted during the removal of a gasoline UST. Former Staff
9/18/1991 Leaking Underground Storage Tank Release Confirmed - Petroleum LUST Site created in CSP for source area ID 76277 ADD; Site assessment report, for the removal of USTs at Stelling Enterprises in Dillingham, submitted to DEC. Report indicates that a release has occurred. Former Staff
9/18/1991 Site Added to Database Former Staff
9/19/1991 Leaking Underground Storage Tank Cleanup Initiated - Petroleum LCAU; :LCAU Date changed DB conversion Former Staff
11/1/1991 Underground Storage Tank Site Characterization or Assessment SA1R; Site Assessment report was submitted to the Central Office in November of 1991, to the financial assistance program in December of 1991 and to the SCRO on March 13, 1992. Review of the report completed on March 13. Soil contamination was identified and residual contamination remains in the ground. Former Staff
11/1/1991 Update or Other Action NOR; Site Assessment Report submitted to the Central Office in November 1991. SCRO received a copy of report on March 13, 1992. Notice of Release Letter sent March 16, 1992. Former Staff
12/30/1993 Leaking Underground Storage Tank Corrective Action Underway CAPR; Proposed plan to landspread contaminated soils approved. Former Staff
1/25/1994 Underground Storage Tank Site Characterization or Assessment SA1R; Site assessment depicted soils above appropriate cleanup levels. Former Staff
11/4/1997 Site Closure Approved Former Staff
11/20/1997 Update or Other Action ADEC sends Notification of Intent to Cost Recover Letter to Current Owner: STELLING ENTERPRISES Former Staff
12/14/2004 Update or Other Action File number 2540.26.007 assigned and entered into the Fileroom database and Leaking Underground Storage Tank database. Alyce Hughey
8/20/2008 Update or Other Action Public inquiry on adjacent property. Cursory review of the 1993 release investigation, 1997 closure sampling, and 1997 correspondence suggests that decision to change site status to "no further assessment or cleanup" to be substantiated by the information in the administrative file. Tank removal in 1993 involved excavating over 300 cubic yards of contaminated soil. Excavation was limited in extent in some directions by site features such as fiber optic cable, concrete pad, building, monitoring well, and heating oil tank. Seven GRO and BTEX confirmation samples with benzene above Method 2 migration to groundwater levels. Benzene ranged from 13 mg/kg to ND with the greater concentrations at the deepest part of the excavation in the northern corner @ ~16 ft bgs. Groundwater samples were to have been collected but water table was reported to be low, so it was intended that a return visit be made in a later attempt to collect groundwater from nearby private wells and/or monitoring well at the edge of the excavation. 1997 closure report included sampling of the landspread soil which resulted in nondetect for BTEX. The monitoring well was again reported to be dry and subsequently abadoned. Estimated amount of soil contamination remaining (~1 cubic yard) suggested to be clay layer. Clay layer could also act as confining layer. Keather McLoone

Contaminant Information

Name Level Description Media Comments
For more information about this site, contact DEC at (907) 465-5390.

Control Type

Type Details
No ICs Required

Requirements

Description Details
Advance approval required to transport soil or groundwater off-site.

There are no documents for this site report.

No associated sites were found.

Missing Location Data

Because the GIS location data for this site has not been entered, we cannot direct you to its position on the map. Click "Continue" to proceed to the Contaminated Sites Web Map or "Close" to return to the site report.