Skip to content Skip to content

Site Report: Saint Elias Auto Center - Yakutat

Site Name: Saint Elias Auto Center - Yakutat
Address: 710 Oil Dock Rd.; , Yakutat, AK 99689
File Number: 1530.26.001
Hazard ID: 24561
Status: Cleanup Complete
Staff: Flannery Ballard, 9074655368 flannery.ballard@alaska.gov
Latitude: 59.544899
Longitude: -139.727761
Horizontal Datum:NAD83

We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.

Problems/Comments

The major initial effort will be to discern the nature, movement, and source of the DRO found in St.Elias Auto private well sample. Efforts are being made to locate positions of the City wells, and any nearby private wells. Farnell was last staff assigned followed by Hung. Hung: note, there are 2 dbs for this site with 2 different reckeys and problems. Event Id 1232 & 1233 possibly created by Farnell?? 12/22/99 file mailed to Paul Horwath for followup. Private well at St.Elias Auto residence contaminated with DRO (410 ug/l). Source is unknown; the history of the site makes it seem unlikely that the site is a source for diesel contamination.

Action Information

Action Date Action Description DEC Staff
10/10/1996 Underground Storage Tank Site Characterization or Assessment 1,500-gallon gasoline UST removed that was installed '84. Contam due to overfilling & piping probs. Highest soil sample results @ 10 ft bgs w/GRO 1,800 ppm, Benzene 5.6 ppm & total BTEX 589 ppm. RPCON recommends on-site & neighboring wells be sampled/analyzed, possible grd water impact with potential for impact to local public water system due to proximity of system to site & conduct RI. Approx 26-100 cu yds contam soil remains. No soils were stockpiled. Former Staff
11/5/1996 Leaking Underground Storage Tank Release Confirmed - Petroleum LUST Site created in CSP for source area ID 77093 ADD; On-site private well contaminated with DRO 410 ug/l (verbally reported by consultant - Woodward-Clyde - on 11/15/96). Awaiting report from consultant. Former Staff
11/5/1996 Site Added to Database Former Staff
12/18/1996 Update or Other Action DEC receives 11/96 SA rept Former Staff
11/16/1997 Release Investigation No significant contamination found @ 10 ft bgs according to 2nd RPCON. Former Staff
11/20/1997 Update or Other Action ADEC sends Notification of Intent to Cost Recover Letter to Current Owner: MIKE EAMES Former Staff
1/15/1998 Update or Other Action DEC receives 12/30/97 RI rept Former Staff
10/11/1999 Leaking Underground Storage Tank Cleanup Initiated - Petroleum Not done contam. Soil still in the pit. Former Staff
11/4/1999 Update or Other Action DEC writes to RPCON re-unacceptable 12/30/97 RI rept entitled, "Confirmation Soil Sampling Report Saint Elias Auto Center." based on inadequate info to support conclusion that site doesn't have significant contam, especially when SA conducted 10/96 by another RPCON found significant contam above ADEC cleanup levels in GRO, Benzene & BTEX, PID was not calibrated when used on-site 11/16/97, but calibrated 11/3/97 in Juneau. Rept lacked necessary data documented when screening soils. Former Staff
12/18/2001 Site Closure Approved NFA letter issued 12/18/01 by Paul Horwath. File shipped from Kenai Office back to Juneau. Paul Horwath
9/9/2024 Brownfields Award DEC Brownfields awarded DBAC services to provide a Phase I ESA for the St. Elias Auto Center property. Marc Thomas
12/2/2024 Update or Other Action DEC received draft Phase I ESA and provided to Yakutat Tlingit Tribe. Met with YTT on 12/9/24 to discuss Phase I and project next steps. Marc Thomas

Contaminant Information

Name Level Description Media Comments
For more information about this site, contact DEC at (907) 465-5390.

Control Type

Type Details
No ICs Required

Requirements

Description Details
Advance approval required to transport soil or groundwater off-site.

No associated sites were found.

Missing Location Data

Because the GIS location data for this site has not been entered, we cannot direct you to its position on the map. Click "Continue" to proceed to the Contaminated Sites Web Map or "Close" to return to the site report.
Continue     Close