Site Report: Saint Elias Auto Center - Yakutat
Site Name: | Saint Elias Auto Center - Yakutat |
---|---|
Address: | 710 Oil Dock Rd.; , Yakutat, AK 99689 |
File Number: | 1530.26.001 |
Hazard ID: | 24561 |
Status: | Cleanup Complete |
Staff: | Flannery Ballard, 9074655368 flannery.ballard@alaska.gov |
Latitude: | 59.544899 |
Longitude: | -139.727761 |
Horizontal Datum: | NAD83 |
![]() | ![]() |
![]() | ![]() |
We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.
Problems/Comments
The major initial effort will be to discern the nature, movement, and source of the DRO found in St.Elias Auto private well sample. Efforts are being made to locate positions of the City wells, and any nearby private wells. Farnell was last staff assigned followed by Hung. Hung: note, there are 2 dbs for this site with 2 different reckeys and problems. Event Id 1232 & 1233 possibly created by Farnell?? 12/22/99 file mailed to Paul Horwath for followup. Private well at St.Elias Auto residence contaminated with DRO (410 ug/l). Source is unknown; the history of the site makes it seem unlikely that the site is a source for diesel contamination.
Action Information
Action Date | Action | Description | DEC Staff |
---|---|---|---|
10/10/1996 | Underground Storage Tank Site Characterization or Assessment | 1,500-gallon gasoline UST removed that was installed '84. Contam due to overfilling & piping probs. Highest soil sample results @ 10 ft bgs w/GRO 1,800 ppm, Benzene 5.6 ppm & total BTEX 589 ppm. RPCON recommends on-site & neighboring wells be sampled/analyzed, possible grd water impact with potential for impact to local public water system due to proximity of system to site & conduct RI. Approx 26-100 cu yds contam soil remains. No soils were stockpiled. | Former Staff |
11/5/1996 | Leaking Underground Storage Tank Release Confirmed - Petroleum | LUST Site created in CSP for source area ID 77093 ADD; On-site private well contaminated with DRO 410 ug/l (verbally reported by consultant - Woodward-Clyde - on 11/15/96). Awaiting report from consultant. | Former Staff |
11/5/1996 | Site Added to Database | Former Staff | |
12/18/1996 | Update or Other Action | DEC receives 11/96 SA rept | Former Staff |
11/16/1997 | Release Investigation | No significant contamination found @ 10 ft bgs according to 2nd RPCON. | Former Staff |
11/20/1997 | Update or Other Action | ADEC sends Notification of Intent to Cost Recover Letter to Current Owner: MIKE EAMES | Former Staff |
1/15/1998 | Update or Other Action | DEC receives 12/30/97 RI rept | Former Staff |
10/11/1999 | Leaking Underground Storage Tank Cleanup Initiated - Petroleum | Not done contam. Soil still in the pit. | Former Staff |
11/4/1999 | Update or Other Action | DEC writes to RPCON re-unacceptable 12/30/97 RI rept entitled, "Confirmation Soil Sampling Report Saint Elias Auto Center." based on inadequate info to support conclusion that site doesn't have significant contam, especially when SA conducted 10/96 by another RPCON found significant contam above ADEC cleanup levels in GRO, Benzene & BTEX, PID was not calibrated when used on-site 11/16/97, but calibrated 11/3/97 in Juneau. Rept lacked necessary data documented when screening soils. | Former Staff |
12/18/2001 | Site Closure Approved | NFA letter issued 12/18/01 by Paul Horwath. File shipped from Kenai Office back to Juneau. | Paul Horwath |
9/9/2024 | Brownfields Award | DEC Brownfields awarded DBAC services to provide a Phase I ESA for the St. Elias Auto Center property. | Marc Thomas |
12/2/2024 | Update or Other Action | DEC received draft Phase I ESA and provided to Yakutat Tlingit Tribe. Met with YTT on 12/9/24 to discuss Phase I and project next steps. | Marc Thomas |
Contaminant Information
Name | Level Description | Media | Comments |
---|---|---|---|
For more information about this site, contact DEC at (907) 465-5390. |
Control Type
Type | Details |
---|---|
No ICs Required |
Requirements
Description | Details |
---|---|
Advance approval required to transport soil or groundwater off-site. |
No associated sites were found.