Site Report: ADOT&PF North Kenai Maintenance Facility
Site Name: | ADOT&PF North Kenai Maintenance Facility |
---|---|
Address: | 51150 Island Lake RoadNorth Kenai, Kenai, AK 99611 |
File Number: | 2320.26.002 |
Hazard ID: | 24699 |
Status: | Cleanup Complete |
Staff: | No Longer Assigned, 9074655229 dec.icunit@alaska.gov |
Latitude: | 60.721069 |
Longitude: | -151.319682 |
Horizontal Datum: | WGS84 |
![]() | ![]() |
![]() | ![]() |
We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.
Problems/Comments
During the removal of one 2,000 gallon diesel, one 2,000 gallon gasoline underground storage tanks, and one 2,500 gallon used oil above ground tank on October 7th and 8th 1997, BTEX concentrations from Non Detect to 31 ppm, GRO concentrations from Non Detect to 850 ppm, and DRO concentrations from Non Detect to 26,000 ppm was encountered. Groundwater was not encountered during the removals, and 15 cubic yards of contaminated soils was stockpiled on site. Updated 1-3-06 Alyce Hughey.
Action Information
Action Date | Action | Description | DEC Staff |
---|---|---|---|
1/7/1998 | Leaking Underground Storage Tank Release Confirmed - Petroleum | LUST Site created in CSP for source area ID 77196 | Former Staff |
1/7/1998 | Site Added to Database | Former Staff | |
10/11/1999 | Leaking Underground Storage Tank Cleanup Initiated - Petroleum | Former Staff | |
6/9/2004 | Update or Other Action | File number assigned and entered into the Fileroom DB and LUST DB. | Alyce Hughey |
6/23/2005 | Update or Other Action | Using Figure 1 from a Summary Report Underground Storage Tank Closure Report DOT&PF Maintenance Facility North Kenai, from AGRA Earth & Environmental, dated December 1997 in conjunction with TopoZone Pro and the KPB Parcel Viewer entered coordinates for this site. Metadata include No Topo Base Map, TopoZone Pro Street Map, Black & White Aerial Photo, on a Medium Size map, View Scale 1:10,000, Coordinate Datum NAD83. High degree of confidence in accuracy of location. | Alyce Hughey |
7/6/2005 | Document, Report, or Work plan Review - other | Reviewed file and report. Sent e-mail to ADOT for any update since the AGRA UST removal report. Site investigation & corrective actions required. | Donald Seagren |
8/4/2005 | Update or Other Action | Sent letter to Dot requesting project status update and copies of all correspondence & reprots sinc ethe AGRA report was issued. Additional assessment &/or corrective action work is required. If nothing furthe has been done, assessment and corrective action work needs to be conducted. | Donald Seagren |
12/1/2005 | Update or Other Action | developed RFP for additional site assessment, cleanup and remediation | Donald Seagren |
3/24/2006 | Underground Storage Tank Site Characterization or Assessment | reviewed and approved Site characterizatin work plan | Donald Seagren |
6/26/2006 | Document, Report, or Work plan Review - other | Reviewed draft assessment report. OK to finalize. No in-situ contamination found exceeding ADEC cleanup standards. Stockpile exceeds for DRO (954 & 949 mg/kg) only. | Donald Seagren |
7/13/2006 | Site Closure Approved | 06 assessment showed that no contamination exceding cleanup levels was found at the site, except in the stockpile. The stockpile will be spread in an unused portion of the facility and fertilized for enhanced final remediation of the DRO contamination. Risk to human health and the environment is minimal. | Donald Seagren |
6/17/2008 | Update or Other Action | Site transferred from Don Seagren to Paul Horwath per Linda Nuechterlein. | Alyce Hughey |
Contaminant Information
Name | Level Description | Media | Comments |
---|---|---|---|
For more information about this site, contact DEC at (907) 465-5390. |
Control Type
Type | Details |
---|---|
No ICs Required |
Requirements
Description | Details |
---|---|
Advance approval required to transport soil or groundwater off-site. |
There are no documents for this site report.