Action Date |
Action |
Description |
DEC Staff |
10/23/1998 |
Site Added to Database |
|
Former Staff |
10/23/1998 |
Leaking Underground Storage Tank Release Confirmed - Petroleum |
LUST Site created in CSP for source area ID 77844 (Added by System) |
Former Staff |
12/17/1998 |
Underground Storage Tank Site Characterization or Assessment |
Site Assessment by Shannon & Wilson recommends conducting Release Investigation and Well Search. |
Former Staff |
12/17/1998 |
Leaking Underground Storage Tank Cleanup Initiated - Petroleum |
entered by JC |
Former Staff |
8/21/2002 |
Update or Other Action |
RECKEY has automatically been generated. |
Cynthia Pring-Ham |
2/23/2004 |
Update or Other Action |
Invitation to apply to Streamlined Cleanup Program sent by letter to owner/RP. |
Bruce Wanstall |
4/22/2005 |
Update or Other Action |
Sent a Notice of Release letter to the owners requesting a Release Investigation. |
Deborah Williams |
11/22/2006 |
Document, Report, or Work plan Review - other |
ADEC reviewed Shannon & Wilson's Underground Storage Tank Assessment report for the World Wide Movers site. In July of 2006, a 14' by 26' excavation was completed in the location of the former diesel tank (Tand3) to a maximum depth of 15 feet bgs. Groundwater was encountered at 13 feet bgs. Approximately 175 cubic yards (2006 excavation) and 40 cubic yards (2005 excavation) of contaminated soil were transported to OIT for thermal remediation. MW-1 was installed in the excavation near the location of the former diesel tank. Soil samples taken from the base of the excavation were all non-detect except for one that had 0.0255 ppm benzene. The samples analyzed for PAHs met ADEC cleanup levels. Sample results from the groundwater at MW-1 had DRO at 8.59 ppm DRO, 1.39 ppm GRO and 33.8 ppb benzene. Shannon & Wilson recommends sampling a groundwater sample from MW-1 during the summer of 2007. |
Deborah Williams |
5/4/2007 |
Exposure Tracking Model Ranking |
Initial ranking completed. |
Deborah Williams |
6/5/2008 |
Update or Other Action |
Received call from RP. Will be submitting workplan in mid June 08 from Shannon & wilson. |
Tamara Cardona-Marek |
10/14/2008 |
Document, Report, or Work plan Review - other |
DEC received from Shannon and Wilson the Groundwater Monitoring Report for well MW-1. DRO continues to be above cleanup levels in this well. Groundwater depth for the recent or historic events was not submitted. DEC requested groundwater depth data and an updated conceptual site model. |
Tamara Cardona-Marek |
11/7/2009 |
Update or Other Action |
Project manager changed from Tamara Cardona-Marek to Jim Fish. |
Janice Wiegers |
10/28/2013 |
Update or Other Action |
Sent a request for information on site status and any pending site work to RP. |
Jim Fish |
11/22/2013 |
Update or Other Action |
Recieved phone call from RP - will plan to sample well in summer 2014, and will forward information collected by S&W subsequent 2008. |
Jim Fish |
11/25/2013 |
Update or Other Action |
Recieved January 9, 2009 letter from RP - describes site summary, S&W's recommendations in 2008, and plans for 2010 sampling. Phone conversation with RP indicated sampling never happend, but will plan for sampling July, 2014. |
Jim Fish |
11/26/2013 |
Update or Other Action |
Received letter from RP indicating sampling plan (MW-1) for July 2014. After receiving results, the site will be evaluated for closure.
|
Jim Fish |
9/11/2014 |
Document, Report, or Work plan Review - other |
Received groundwater sampling report from consultant |
Jim Fish |
10/6/2014 |
Update or Other Action |
Sent a letter to the RP asking for clarification of waste oil tank and UIC identified during 1989 EPA inspection. |
Jim Fish |
10/14/2014 |
Update or Other Action |
Received a phone from RP in response to 10/6 letter - indicated that there was no waste oil tank. Suggested he contact EPA UIC Program and clarify.
|
Jim Fish |
4/10/2015 |
Update or Other Action |
Requested RP contact EPA Region 10 UIC Program to follow-up with suspected waste oil tank and UIC identified during 1989 EPA inspection. |
Jim Fish |
4/17/2015 |
Update or Other Action |
Letter from UST Program sent to RP requiring closure of Oil/water separator UST, that stored used oil, by August 30, 2015. |
Jim Fish |
7/24/2015 |
Update or Other Action |
Received UST and UIC closure work plan from consultant |
Jim Fish |
8/17/2015 |
Document, Report, or Work plan Review - other |
Received amended work plan for UST and UIC closure.
|
Jim Fish |
8/18/2015 |
Meeting or Teleconference Held |
teleconference with consultant held to clarify approach to UIC assessment and adherence to UST regualtions |
Jim Fish |
8/21/2015 |
Update or Other Action |
Received second revised UST & UIC Closure work plan. |
Jim Fish |
8/24/2015 |
Update or Other Action |
Received USEPA UIC Program approval of UIC closure plan. |
Jim Fish |
8/25/2015 |
Site Characterization Workplan Approved |
Conditionally approved revised UST and UIC closure work plan, submitted 21 August, 2015.
|
Jim Fish |
12/10/2015 |
Document, Report, or Work plan Review - other |
Received UST and UIC Site Assessment Closure Report from consultant. PCE above cleanup levels found at the soil-groundwater interface beneath the UST and UST piping, as well as in the soils of soil adsorption system (leach field). PCE was also detected in groundwater (below cleanup levels) beneath the soil adsorption system. Additional Release Investigation recommended by consultant. |
Jim Fish |
3/31/2016 |
Update or Other Action |
Sent a letter to the RP requesting additional site investigation of soil and groundwater contamination at the SAS, under the former OWS, and under the building; and to determine if contaminated groundwater is moving off-site. Requested 4-inch roof drain pipe currently plumbed to former SAS be rerouted to avoid spreading remaining soil contamination; Requested remediation or removal of contaminated soil if they pose a risk to building occupants; Also advised coordination with EPA Region 10 UIC Program for reclassification or closure of the MVWDW. |
Jim Fish |
9/27/2016 |
Document, Report, or Work plan Review - other |
Received work plan for release investigation at the former used oil UST and UIC soil absorption system; groundwater sampling & monitoring, as well as sub-soil gas collection beneath the WWM building. |
Jim Fish |
11/18/2016 |
Site Characterization Workplan Approved |
Revised work plan for release investigation, with soil sampling, groundwater sampling (involving both temporary and permanent monitoring wells), and sub-slab soil gas sampling, approved. |
Jim Fish |
12/13/2016 |
Update or Other Action |
Reviewed and approved request to decommission soil stockpile from October 2015 UST excavation activities, and concurred with the determination that excavated soils did not contain listed of characteristic hazardous waste. Soils approved for reuse on the site as fill material. |
Jim Fish |
4/5/2017 |
Update or Other Action |
Received release Investigation Letter report from consultant |
Jim Fish |
4/14/2017 |
Meeting or Teleconference Held |
Discussed Release Investigation report and changed groundwater cleanup levels with RP and consultant, and agreed on evaluating vapor intrusion potential in building, and investigating groundwater for contaminants found in sub-slab soil gas. |
Jim Fish |
6/1/2017 |
Update or Other Action |
received updated/revised work plan addendum for indoor air sampling and grounndwater sampling from former oil/water separator. |
Jim Fish |
6/8/2017 |
Document, Report, or Work plan Review - other |
Addendum to Release Investigation Work Plan approved. Indoor air sampling in office space will be conducted, and if contaminants are identified in groundwater from beneath the oil-water separator in excess of their ADEC cleanup levels, the extent and magnitude of the contamination will be determined. |
Jim Fish |
3/16/2018 |
Document, Report, or Work plan Review - other |
2017 Release investigation report received, documenting last year’s groundwater and indoor-air sampling and oil/water separator closure activities at the site |
Jim Fish |
5/14/2018 |
Exposure Tracking Model Ranking |
Initial ranking with ETM completed for source area id: 80226 name: Used Oil UST 4 |
Jim Fish |
5/14/2018 |
Exposure Tracking Model Ranking |
A new updated ranking with ETM has been completed for source area 80226 Used Oil UST 4. |
Jim Fish |
5/14/2018 |
Exposure Tracking Model Ranking |
A new updated ranking with ETM has been completed for source area 77844 USTs 1-3. |
Jim Fish |
4/17/2019 |
Document, Report, or Work plan Review - other |
DEC received the site closure request. |
Megan Roberts |
4/30/2019 |
Update or Other Action |
DEC decided to separate the site based on source areas due to the regulated tanks #1-#4 being ready for closure. See other site file World Wide Movers Class V Inj Well & OWS 102.38.203 for the other source areas. |
Megan Roberts |
5/30/2019 |
Cleanup Complete Determination Issued |
DEC determined the site no longer poses an unacceptable risk to human health or the environment. This Cleanup Complete determination is based on the administrative record for the World Wide Movers. |
Megan Roberts |