Skip to content Skip to content

Site Report: City of Valdez Public Library

Site Name: City of Valdez Public Library
Address: 260 Fairbanks Drive, Valdez, AK 99686
File Number: 2264.38.036
Hazard ID: 25484
Status: Cleanup Complete
Staff: No Longer Assigned, 9074655229 dec.icunit@alaska.gov
Latitude: 61.129444
Longitude: -146.354444
Horizontal Datum:WGS84

We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.

Problems/Comments

During the removal of one 1,028-gallon non-regulated heating oil underground storage tank (UST) on August 27, 2009, diesel soil contamination was encountered at 5.5 feet below ground surface at the east sidewall of the excavation at approximately 2 feet from the building at concentrations of 910 milligrams per kilogram (mg/kg) and at 7.75 feet below ground surface beneath the east side of the UST at concentrations of 1,990 mg/kg. Approximately 20 cubic yards of contaminated soil was excavated from the UST excavation and transported to the City of Valdez Bailer Facility with diesel range organic (DRO) soil concentrations of 9,760 mg/kg and Benzo(a)pyrene soil concentrations of 1.01 mg/kg. When the tank was removed, floating product was observed in the excavation at approximately 6 feet below ground surface on the east side of the excavataion. An additional two feet of soil was excavated to approximatley 8 feet below ground surface along the east side of the tank excavation. The upper aquifer was measured in a groundwater sump adjacent to the site at approximately 13 feet below ground surface. Groundwater was not observed in the tank excavation.

Action Information

Action Date Action Description DEC Staff
1/14/2010 Site Added to Database A new site has been added to the database Alyce Hughey
1/14/2010 Exposure Tracking Model Ranking Initial ranking with ETM completed for source area id: 78844 name: Underground Storage Tank Alyce Hughey
1/13/2012 Update or Other Action Project Manager changed from Paul Horwath to Peter Campbell per Paul Horwath. Alyce Hughey
2/14/2012 Update or Other Action Letter to the City of Valdez requesting a soil treatment workplan from soils that were moved from the library to the Bailer Facility that have been undergoing land farming treatment. Request a work plan from the City for the installation of two monitoring wells at the Library by May 1, 2012. Peter Campbell
5/29/2013 Document, Report, or Work plan Review - other Review “Site Assessment Work Plan, Valdez Library” for the former heating oil UST. Also review “Sample/Test Stockpiled Soil, City of Valdez Bailer Facility” work plan for petroleum impacted soils stockpiled during the removal of the Library UST. Peter Campbell
6/17/2013 Site Characterization Workplan Approved Review and approve the "Site Assessment Workplan, Valdez Public Library Former UST." Peter Campbell
6/17/2013 Site Characterization Workplan Approved Review and approve the work plan for “Sample/Test Stockpiled Soil, City of Valdez Bailer Facility.” Peter Campbell
11/5/2013 Potentially Responsible Party/State Interest Letter Peter Campbell
11/14/2013 Potentially Responsible Party/State Interest Letter Certified mail return receipt, received in Soldotna Office on 11-14-13. Alyce Hughey
1/14/2014 Exposure Tracking Model Ranking A new updated ranking with ETM has been completed for source area 78844 Underground Storage Tank. Alyce Hughey
3/4/2014 Update or Other Action Received and approved a work plan for the removal of site monitoring wells to be abandoned this spring. Peter Campbell
8/7/2015 Document, Report, or Work plan Review - other Received Confirmation of Monitoring Well Decommissioning and request for Closure, dated 8-4-15 Review file and finish closure process. Peter Campbell
3/28/2019 Exposure Tracking Model Ranking A new updated ranking with ETM has been completed for source area 78844 Underground Storage Tank. Peter Campbell
4/8/2019 Cleanup Complete Determination Issued Peter Campbell

Contaminant Information

Name Level Description Media Comments
DRO < Method 2 Most Stringent Soil

Control Type

Type Details
No ICs Required

Requirements

Description Details
Advance approval required to transport soil or groundwater off-site.
Movement or use of contaminated material (including on site) in a manner that results in a violation of the water quality standards is prohibited (18 AAC 70)

No associated sites were found.

Missing Location Data

Because the GIS location data for this site has not been entered, we cannot direct you to its position on the map. Click "Continue" to proceed to the Contaminated Sites Web Map or "Close" to return to the site report.