Site Report: UAF Northwest Campus Parking
We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.
Problems/Comments
During a geotechnical study performed by Shannon and Wilson in 2008 to develop geotechnical design recommendations for new foundations for the main university building and the library, seven borings were drilled and samples collected. Soil borings were screened with a photo ionization detector (PID) and laboratory confirmation samples collected from areas with highest PID. Potential surface soil contamination based on PID reading within the parking lot area. Select samples were analyzed for gasoline range (GRO), diesel range (DRO), and residual range organics (RRO), and benzene, toluene, ethylbenzene, and xylenes (BTEX). RRO ranged from 961 to 3,390 parts per million (ppm). DRO concentrations ranged from 98.7 to 1,140 ppm. GRO and BTEX were below DEC cleanup levels. Highest contamination was found at a depth of 5 to 6.5 feet. Total depth of borings was between 35 and 75 feet below ground surface. Permafrost estimated at approximately 9 to 50 feet. Water table after boring completion reported as 40 to 50 feet. No groundwater was encountered on boring that was 35 feet deep.
Action Information
Contaminant Information
Name |
Level Description |
Media |
Comments |
DRO |
Between Method 2 Migration to Groundwater and Human Health/Ingestion/Inhalation |
Soil |
|
RRO |
Between Method 2 Migration to Groundwater and Human Health/Ingestion/Inhalation |
Soil |
|
Control Type
Type |
Details |
No ICs Required |
|
Requirements
Description |
Details |
Advance approval required to transport soil or groundwater off-site. |
|
Movement or use of contaminated material (including on site) in a manner that results in a violation of the water quality standards is prohibited (18 AAC 70) |
|
Hazard ID |
Site Name |
File Number |
4207 |
East Front Street Contamination - Nome |
400.38.037 |
25485 |
UAF Northwest Campus Heating Oil Tank |
400.38.045 |