We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.

Problems/Comments

An intact UST (3.1 ft diameter, 5 ft long) and associated pipeline were found near the former mess hall. In 2000, 110 gallons of water was pumped from the tank and 10 cubic yards of soil were excavated to bedrock, resulting in a 150 square foot excavation that was backfilled with clean soil. Three 30' section of pipe were removed. Six soil samples were taken from the excavation. One sample contained DRO above the Method 2 cleanup levels at 1,810 mg/kg, but below the ACL of 8,300 mg/kg. All other analytes were below cleanup criteria.

Action Information

Action Date Action Description DEC Staff
2/8/2012 Site Added to Database A new site has been added to the database Mitzi Read
11/3/2022 Exposure Tracking Model Ranking Initial ranking with ETM completed for source area id: 79256 name: LSA Bldg 1154 (Mess Hall) Cascade Galasso-Irish
10/27/2023 Document, Report, or Work plan Review - other On this date, DEC reviewed the Site Investigation Visit Technical Memorandum: CON/HTRW, Limited Removal Action, Amaknak FUDS for the Summer Bay-Humpy Cove Power Plant UST, and Little South America Latrine 1 UST and Mess Hall sites. This tech memo is a field visit work plan with limited sampling to guide the 2024 field work and removal actions at the three sites. Cascade Galasso-Irish
3/27/2024 Document, Report, or Work plan Review - other DEC reviewed and provided comments on the Draft Work Plan, CON/HTRW Limited Removal Action, Amaknak FUDS F10AK0841-15, Summer Bay-Humpy Cove, and Amaknak FUDS F10AK0841-20 Little South America, Unalaska, Alaska, dated March 2024. The work plan describes the project approach and methods to be used while conducting environmental removal actions at select Amaknak Formerly Used Defense Sites (FUDS) on Unalaska and Amaknak Islands, Alaska during the 2024 field season. Sarah Bernhardt
11/6/2024 Site Visit On this date DEC personnel conducted a site visit. The Mess Hall was located in a fairly level area near Latrine 1. The building and USTs (possibly two USTs at the site?) have been removed. No debris, but some pipes remain. USACE and the contractor are unsure of where the UST was located. Discussed consulting maps from 1998 removal actions and how to proceed with sampling due to uncertainty of the UST location. Pipes may indicate where the UST was located. Previous report stated that the pipes had been removed. Kathleen Iler-Galau
11/6/2024 Meeting or Teleconference Held The Qawalangin FUDS Restoration Advisory Board (RAB) Meeting was held at the Unalaska Public Library. This regional RAB incorporates five FUDS in the Qawalangin region: Amaknak FUDS, Chernofski FUDS, Cape Wislow FUDS, Fort Learnard FUDS, and Ugadaga Bay FUDS. RAB Board Members, USACE-FUDS, DEC, and members of the public were in attendance in-person, with additional stakeholders participating virtually. FUDS PMs provided updates on the status of FUDS sites. The RAB membership also updated their charter and added new members. Kathleen Iler-Galau
4/28/2025 Document, Report, or Work plan Review - other DEC and USACE resolved comments on the Work Plan for the Humpy Cove Power Plant UST, LSA Building, 1154 and LSA Latrine 1 for the 2025 field season. Expect the final draft within 10 days. Kathleen Iler-Galau