We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.
Problems/Comments
In August 2012, a 300-gallon Doyon Utilities gasoline underground storage tank (UST), DEC ID #3 / aka ADEC #87 [FGA#443A] was removed at Building 625 at Fort Greely. Soil fro the limits of the excavation and the stockpile were sampled for GRO, BTEX, Lead, and PAHs. Some PAHs were detected, but below DEC's most stringent cleanup levels.
Action Information
Action Date | Action | Description | DEC Staff |
---|---|---|---|
8/6/2012 | Leaking Underground Storage Tank Cleanup Initiated - Petroleum | The 300-gallon gasoline underground storage tank at Doyon Utilties at Fort Wainwright Building 625 was removed on this date. | Melody Debenham |
12/17/2012 | Site Added to Database | A new site has been added to the database | Mitzi Read |
12/17/2012 | Leaking Underground Storage Tank Release Confirmed - Petroleum | LUST site created in CSP database for source area 300-Gal Gasoline UST (DEC ID #3 / aka ADEC #87 [FGA#443A]), 79377 | Mitzi Read |
2/4/2013 | Exposure Tracking Model Ranking | Initial ranking with ETM completed for source area id: 79377 name: 300-Gal Gasoline UST (DEC ID #3 / aka ADEC #87 [FGA#443A]) | Melody Debenham |
2/8/2013 | Final Cleanup Report Reviewed | During tank removal activities the 300-gallon gasoline UST was observed to be in good condition and no indications of a release were observed. Analytical samples were collected from the limits of the excavation and the excavated soils and analyzed for gasoline range organics (GRO), benzene, toluene, ethylbenzene, and xylenes (BTEX), lead, and polynuclear aromatic hydrocarbons (PAHs). GRO and BTEX results were all non-detect; lead and 6 PAHs were detected below the migration to groundwater cleanup levels. | Melody Debenham |
2/8/2013 | Cleanup Complete Determination Issued | Melody Debenham |
Contaminant Information
Name | Level Description | Media | Comments |
---|---|---|---|
Fluoranthene | < Method 2 Most Stringent | Soil | |
Phenanthrene | < Method 2 Most Stringent | Soil | |
Chrysene | < Method 2 Most Stringent | Soil | |
Benzo(a)anthracene | < Method 2 Most Stringent | Soil | |
Benzo(a)pyrene | < Method 2 Most Stringent | Soil | |
Benzo(b)fluoranthene | < Method 2 Most Stringent | Soil | |
Lead - Total | < Method 2 Most Stringent | Soil |
Control Type
Type | Details |
---|---|
No ICs Required |
Requirements
Description | Details |
---|---|
Advance approval required to transport soil or groundwater off-site. |
Hazard ID | Site Name | File Number |
---|---|---|
3089 | Fort Greely P. 56 Bldg 625 Chemical | 141.38.038 |