Skip to content Skip to content

Site Report: Goose Bay Nike Site Battery Control Area

Site Name: Goose Bay Nike Site Battery Control Area
Address: Cameo Drive; NW of W End of Goose Bay Airstrip, ~10 Miles SSW of Big Lake, Big Lake, AK 99652
File Number: 2226.38.006
Hazard ID: 25974
Status: Active
Staff: Sarah Bernhardt, 9072697527 sarah.bernhardt@alaska.gov
Latitude: 61.396277
Longitude: -149.857967
Horizontal Datum:WGS84

We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.

Problems/Comments

Two 20,000-gallon underground storage tanks were assumed to be removed when the site was demolished, however no documentation of tank and soil removal was found. In 2012 the USACE investigated the site using an Ultra-Violet Optical Screening Tool (UVOST) and encountered plumes of Arctic grade diesel and dyed heating oil in the subsurface surrounding the former tank locations. Ten samples were collected and analzyed for GRO, DRO, RRO, BTEX, 1,2-DCA, EDB, and PAH. Several samples showed exceedances of DRO and several PAHs.

Action Information

Action Date Action Description DEC Staff
1/3/2013 Site Added to Database A new site has been added to the database Mitzi Read
1/11/2013 Exposure Tracking Model Ranking Initial ranking with ETM completed for source area id: 79383 name: Two 20,000-Gal USTs - Arctic Grade Diesel Meghan Dooley
1/28/2013 Site Characterization Report Approved ADEC approved of the UVOST Site Investigation Report for the Battery Control Area. In 2012 the USACE conducted an Ultra Violet Optical Screening Tool (UVOST) investigation to determine the presence or absence of underground storage tanks as well as associated pipelines and contaminated soil. The tanks were found to have already been removed. The investigation did uncover 2 plumes of arctic grade diesel and heating oil in the location of the former tanks. Contamination ranges from 8 feet below ground surface (BGS) to as deep as 24 feet bgs. A remedial action is planned for 2014. Meghan Dooley
5/19/2016 Update or Other Action Phase II RI was anticipated in summer 2016, but the USACE has been unable to secure right of entry from the University of Alaska and DNR. Coordination is ongoing and work is anticipated in Summer 2017. Holly Weiss-Racine
6/27/2017 Site Visit ADEC staff visited the Site and met with Army Corp, their contractors and land owner (University of Alaska) representative. Land owner representative gave a site tour and site history introduction. The 2017 field activities by the Corp are targeted only for subsurface PCE/TCE delineation at the Launch Facility Area (Haz ID 25355). Linda (Qi) Liu

Contaminant Information

Name Level Description Media Comments

Control Type

Type Details

Requirements

Description Details

There are no documents for this site report.

Hazard ID Site Name File Number
3175 ADNR Goose Bay Nike Admin. & Prison Site 2226.38.004

Missing Location Data

Because the GIS location data for this site has not been entered, we cannot direct you to its position on the map. Click "Continue" to proceed to the Contaminated Sites Web Map or "Close" to return to the site report.