Skip to content Skip to content

Site Report: GSA Federal Bldg Motor Pool

Site Name: GSA Federal Bldg Motor Pool
Address: 101 12th Avenue, Fairbanks, AK 99701
File Number: 102.38.174
Hazard ID: 26035
Status: Cleanup Complete
Staff: No Longer Assigned, 9074655229 dec.icunit@alaska.gov
Latitude: 64.837404
Longitude: -147.708685
Horizontal Datum:WGS84

We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.

Problems/Comments

In March 2013 approximately 1,000 to 1,500 gallons of propylene glycol were released from the piping of a radiant slab heating system in the floor of the motor pool annex at the Federal Building at 101 12th Avenue in Fairbanks.

Action Information

Action Date Action Description DEC Staff
4/8/2013 Spill Transferred from Prevention Preparedness and Response Program Spill transferred by PERP staff Paul Lhotka. Spill no. 13309908601; spill date = 3/27/13; substance - propylene glycol (Dowfrost heat transfer fluid, MSDS #1376); quantity = ~1,000-1,500 gallons; PERP file no. 100.02.155. Mitzi Read
4/17/2013 Site Added to Database A new site has been added to the database Mitzi Read
4/18/2013 Exposure Tracking Model Ranking Initial ranking with ETM completed for source area id: 79442 name: 1,000-1,500 Gal Propylene Glycol Release Mitzi Read
5/8/2013 Potentially Responsible Party/State Interest Letter Melody Debenham
5/10/2013 Site Characterization Workplan Approved Approved the final work plan for site investigation to determine if there are soil or groundwater impacts associated with the glycol release. The contractor will install 8 direct push soil borings and 8 direct push temporary groundwater monitoring points. Soil and groundwater samples will be analyzed for ethylene glycol and propylene glycol. Melody Debenham
5/10/2013 Cleanup Level(s) Approved ADEC chemist calculated propylene glycol cleanup levels for this site. Soil cleanup level (migration to groundwater) is 828 mg/kg. Groundwater cleanup level is 312 mg/L. Melody Debenham
9/19/2014 Site Characterization Report Approved Received Glycol Release Investigation Report. Results show that ethylene glycol was detected in one soil sample above the migration to groundwater cleanup level but below the direct contact cleanup level. No ethylene glycol or propylene glycol was detect in the groundwater samples. Melody Debenham
9/25/2014 Exposure Tracking Model Ranking A new updated ranking with ETM has been completed for source area 79442 1,000-1,500 Gal Propylene Glycol Release. Melody Debenham
10/24/2014 Cleanup Complete Determination Issued Melody Debenham

Contaminant Information

Name Level Description Media Comments
Ethylene Glycol Between Method 2 Migration to Groundwater and Human Health/Ingestion/Inhalation Soil

Control Type

Type Details
No ICs Required

Requirements

Description Details
Advance approval required to transport soil or groundwater off-site.
Hazard ID Site Name File Number
24347 GSA Federal Bldg Motor Pool Equip. Bldg 102.26.084

Missing Location Data

Because the GIS location data for this site has not been entered, we cannot direct you to its position on the map. Click "Continue" to proceed to the Contaminated Sites Web Map or "Close" to return to the site report.