Skip to content Skip to content

Site Report: Commercial Property - 619 East 5th Avenue UST #2

Site Name: Commercial Property - 619 East 5th Avenue UST #2
Address: 619 East 5th Avenue, Anchorage, AK 99501
File Number: 2100.26.588
Hazard ID: 26338
Status: Cleanup Complete
Staff: Janice Wiegers, 9074512127 janice.wiegers@alaska.gov
Latitude: 61.217858
Longitude: -149.872439
Horizontal Datum:WGS84

We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.

Problems/Comments

In October 2014, following demolition of two buildings (the Former West addition, a maintenance shop, and the Former East Structure, a storage building), Tank #2, a regulated 1,000-gallon gasoline underground storage tank (UST) and associated piping were removed. The lot is currently vacant. The base of the excavation, after the tank removal, at approximately 7 feet bgs, exceeded applicable cleanup levels for gasoline range organics (GRO), toluene, ethylbenzene, and total xylenes at 2,080 mg/Kg, 14.6 mg/Kg, 41.4 mg/KG, and 613 mg/Kg, respectively. Groundwater was not encountered during the excavation and is believed to be greater than 35 feet below the ground surface.

Action Information

Action Date Action Description DEC Staff
1/26/2015 Potentially Responsible Party/State Interest Letter Potentially Responsible Party / State Interest letter sent to Hickel Investment Company. Lisa Krebs-Barsis
1/28/2015 Site Added to Database A new site has been added to the database Mitzi Read
2/6/2015 Exposure Tracking Model Ranking Initial ranking with ETM completed for source area id: 79732 name: 1,000-Gallon Gasoline UST #2 Lisa Krebs-Barsis
6/2/2015 Site Characterization Workplan Approved Reviewed and approved of site characterization work plan submitted by the RP's consultant. One boring within the footprint of the original excavation will be advanced to groundwater. No groundwater monitoring is anticipated for this investigation. Characterization work on the UST will be conducted simultaneously with work at the collocated heating oil tank site (2100.38.551). Lisa Krebs-Barsis
6/25/2015 Site Visit Visited the site to observe the advancement of boreholes. Lisa Krebs-Barsis
10/20/2015 Site Characterization Report Approved Reviewed the site characterization report submitted on August 18, 2015. Seven bore holes were advanced near the heating oil tank release. Groundwater was encountered at 35 feet below the ground surface (bgs). Diesel range organics at concentrations of 631 mg/Kg were detected at 30 feet bgs in Boring 6 (near the former dispenser and at the south end of the heating oil tank excavation) and 2720 mg/Kg at Boring 1 (within the former UST footprint). Gasoline range organics were detected at levels below the most stringent migration to groundwater cleanup level. A work plan to investigate groundwater was requested. Lisa Krebs-Barsis
11/13/2015 Site Characterization Workplan Approved Approved of work plan to install and sample three groundwater monitoring wells on Lots 25 and 26. Lisa Krebs-Barsis
1/29/2016 Site Characterization Report Approved Three monitoring wells were installed, two on Lot 25 (MW2, MW3) and one on Lot 26 (MW1). Groundwater was found approximately 35 feet below ground surface and was determined to flow to the north east. MW3 was placed in the source area. Samples collected from the each of the wells were analyzed for DRO, RRO, GRO, and BTEX. The sample from MW3 was also analyzed for PAH. None of the analytes were detected in any of the samples. Lisa Krebs-Barsis
3/21/2016 Document, Report, or Work plan Review - other Reviewed groundwater sampling work plan for 619 East 5th Ave. Monitoring wells MW-1, MW-2, and MW-3 will be purged and sampled for DRO, GRO, and BTEX. The sample from MW-3 will also be analyzed for PAHs. Bill O'Connell
7/7/2016 Document, Report, or Work plan Review - other Reviewed Groundwater Sampling Event No. 2 Report from the 619 East 5th Ave. property dated 7/7/2016. Samples were taken from 3 monitoring wells on June 17, 2016. The samples were analyzed for GRO, DRO, and BTEX. MW-1 was also analyzed for PAH. No analytes were detected in any of the samples. Darren Mulkey
8/11/2016 Cleanup Complete Determination Issued After the second round of groundwater samples with no exceedance of drinking water standards, the Decision Document was issued. Darren Mulkey
8/19/2016 Update or Other Action Groundwater wells were decommissioned by Montauk with no complications. Darren Mulkey

Contaminant Information

Name Level Description Media Comments
Toluene < Table C Groundwater After the second round of groundwater samples with no exceedance of drinking water standards, the Decision Document was issued.
Ethylbenzene < Table C Groundwater After the second round of groundwater samples with no exceedance of drinking water standards, the Decision Document was issued.
Xylenes (total) < Table C Groundwater After the second round of groundwater samples with no exceedance of drinking water standards, the Decision Document was issued.
GRO < Table C Groundwater After the second round of groundwater samples with no exceedance of drinking water standards, the Decision Document was issued.

Control Type

Type Details
No ICs Required

Requirements

Description Details
Advance approval required to transport soil or groundwater off-site.
Movement or use of contaminated material (including on site) in a manner that results in a violation of the water quality standards is prohibited (18 AAC 70)
Hazard ID Site Name File Number
26333 Commercial Property - 619 East 5th Avenue 2100.38.551
26240 Fairview Areawide Brownfield Assessment 2100.57.020

Missing Location Data

Because the GIS location data for this site has not been entered, we cannot direct you to its position on the map. Click "Continue" to proceed to the Contaminated Sites Web Map or "Close" to return to the site report.
Continue     Close