Skip to content Skip to content

Site Report: East Addition Subdivision Block 20 Alley

Site Name: East Addition Subdivision Block 20 Alley
Address: Alley between Cordova and Denali Streets, between 5th and 6th Avenues, East Addition Subdivision, Block 20, Anchorage, AK 99501
File Number: 2100.38.552
Hazard ID: 26360
Status: Non-Qualifying
Staff: No Longer Assigned, 9074655229 dec.icunit@alaska.gov
Latitude: 61.217056
Longitude: -149.878744
Horizontal Datum:WGS84

We make every effort to ensure the data presented here is accurate based on the best available information currently on file with DEC. It is therefore subject to change as new information becomes available. We recommend contacting the assigned project staff prior to making decisions based on this information.

Problems/Comments

Tetrachloroethylene was detected in soil gas along the alley between 300 East 5th Avenue and 555 Cordova Street. Alaska Cleaners is located along the north side of the alley and a sewer line runs the length of the alley between Cordova Street and Denali Street.

Action Information

Action Date Action Description DEC Staff
3/17/2015 Site Added to Database A new site has been added to the database Mitzi Read
3/20/2015 Update or Other Action PCE contamination was first noted in indoor air at the 555 Cordova Street office building, resulting in the installation and operation of a sub-slab depressurization system. Indoor air was also sampled at the Alaska Cleaners Building, but no contaminants were detected above DEC vapors intrusion screening levels. Bill O'Connell
3/20/2015 Exposure Tracking Model Ranking Initial ranking with ETM completed for source area id: 79744 name: East Addition Subdivision Block 20 Alley Bill O'Connell
1/6/2016 Meeting or Teleconference Held Meeting today with Anchorage Water and Wastewater Utility to discuss condition of sewer line located on Block 20 alley Bill O'Connell
5/18/2016 Document, Report, or Work plan Review - other Reviewed work plan for soil gas investigation, East Addition Subdivision, Block 20. Passive soil gas samplers will be deployed at 14 locations near the intersection of 5th Ave and Cordova St to evaluate the extent of soil gas impacts and provide information to support future investigation in the area. Bill O'Connell
9/19/2016 Document, Report, or Work plan Review - other Reviewed Report for East Addition Block 20 Alley Soil Gas Investigation. Passive soil gas samplers were deployed at 14 locations in the vicinity of Cordova St and 5th Ave in Anchorage. PCE was detected in 10 of the samples ranging from 0.03 ug/m3 to 4.24 ug/m3. The highest concentration was detected along the south side of Cordova St near Office Depot. None of the detected concentrations exceeded ADEC screening levels for the vapor intrusion pathway. Bill O'Connell
6/12/2017 Document, Report, or Work plan Review - other Reviewed Indoor Air Sampling Report for 555 Cordova. Passive samplers were deployed in the basement and on floors 1-5. None of the samples exceeded the target level of 41 ug/m3 for PCE, except one sample in the basement that contained PCE at 330 ug/m3. The system was apparently operating at reduced efficiency immediately preceding the sampling effort and once the system was optimized, follow up samples from the same area contained PCE at 5.2 ug/m3 Bill O'Connell
2/25/2019 Document, Report, or Work plan Review - other Reviewed 2019 Subslab Depressurization System Inspection and Analysis Report for 555 Cordova Street. The system inspection indicates the system is operating as designed and no adverse impacts to the system or the slab from the 2018 earthquake were observed. A sample from the system influent contained PCE at 17,000 ug/m3, which the lowest measured concentration to date since the system began operating in 2015. System monitoring will continue on a weekly basis and the next sampling is scheduled for 2020. Bill O'Connell
8/2/2019 Document, Report, or Work plan Review - other Indoor air samples were collected from 5 locations in the basement of 555 Cordova St in February 2019. PCE was not detected in samples from two locations. PCE concentrations in the other three samples ranged from 1.3 to 1.6 ug/m3, below the ATSDR minimum risk level/DEC residential screening level of 41 ug/m3. Bill O'Connell
11/26/2019 Update or Other Action Site status changed to nonqualifying. Information pertaining to this releases is being tracked under File #2100.38.493 Snow White Cleaners Bill O'Connell

Contaminant Information

Name Level Description Media Comments

Control Type

Type Details

Requirements